Table of Contents
ToggleAn SCR blocks until something pushes its middle junction into conduction, and there are five ways to do that. Only gate triggering gives you a controlled, repeatable firing instant, so most of what follows is about the gate and how to drive it.
Overvoltage, a fast rising voltage, heat, light or a gate signal can all switch on an SCR. Here we compare SCR triggering methods and size a gate resistor.

What are SCR triggering methods and which one is used in practice?
SCR triggering methods are the ways to drive a forward biased SCR from its blocking state into conduction: forward voltage triggering, dv/dt triggering, temperature triggering, light triggering and gate triggering. In practice we use gate triggering, usually with short pulses through a pulse transformer or optocoupler. For example, a 12 V pulse through a 175 ohm resistor pushes 60 mA into a gate rated 30 mA IGT.
What Are SCR Triggering Methods?
SCR triggering methods are the ways we turn a forward biased silicon controlled rectifier from its blocking state into its conducting state. Five physical effects can do it, and gate triggering is the only one engineers use on purpose in a working circuit.
- With anode positive, the middle junction J2 of the PNPN structure blocks current.
- Forward voltage, dv/dt and temperature turn on are treated as faults.
- Gate triggering can be DC, AC or pulse; pulse is preferred.
- Once latched, the SCR stays on until anode current falls below IH.
How Does an SCR Turn On?
An SCR turns on when the current gains of its two internal transistors add up to one, at which point the device latches by positive feedback. Every one of the SCR triggering methods is just a different way of raising that gain.
Picture the PNPN structure as a PNP transistor and an NPN transistor connected so that the collector of each drives the base of the other. Our pages on silicon controlled rectifiers and transistor basics cover the structure in more detail.
IA = (α2 × IG + ICBO1 + ICBO2) / 1 minus (α1 + α2)
When α1 + α2 approaches 1, IA is limited only by the load
General Electric introduced the SCR in 1957, and it quickly replaced mercury arc rectifiers in industrial drives.
What Are the Turn On Methods of SCR?
The five turn on methods of an SCR are forward voltage triggering, dv/dt triggering, temperature triggering, light triggering and gate triggering. The first three usually happen by accident, light triggering suits special high voltage valves, and gate triggering is the everyday method.
Anode voltage raised above the breakover voltage VBO with the gate open makes J2 avalanche and the device latch.
A fast rising anode voltage charges the J2 junction capacitance, and the charging current i = C × dv/dt acts like a gate current.
Leakage across J2 rises steeply with temperature and can fire the SCR without a gate signal.
Photons near J2 create electron hole pairs that act as gate current in a light activated SCR (LASCR).
A gate to cathode current above IGT fires the SCR at the instant you choose.
| Method | Trigger source | Controlled? | Typical status |
|---|---|---|---|
| Forward voltage | Anode voltage above VBO | No | Can damage the device |
| dv/dt | C × dv/dt current at J2 | No | False firing, needs snubber |
| Temperature | Leakage rise at J2 | No | Thermal runaway risk |
| Light | Photons near J2 | Yes | LASCR and HVDC valves |
| Gate | Gate current above IGT | Yes | Standard method |
Littelfuse explains in its thyristor application note that when C dv/dt becomes equal to or greater than the thyristor IGT, the device switches on. So a fast line transient can fire an SCR with no gate signal at all.
Why Is Gate Triggering Preferred?
Gate triggering is preferred because you fire the SCR at an exact, repeatable instant with little power, while the other effects depend on line transients, heat or breakdown. Of all the SCR triggering methods, it is the one that gives you practical phase control.
- Firing angle control from 0 to nearly 180 degrees
- Low trigger power
- Isolation through a pulse transformer or optocoupler
- Easy synchronisation with the 50 Hz supply
- No control over the firing instant
- Possible damage at breakover
- Dependence on transients and temperature
- False firing that can short a converter leg
Check the datasheet for IGT and VGT at the lowest operating temperature, not at 25 °C. Gate sensitivity falls as the junction gets colder, so a circuit that fires on the bench can fail in a cold panel.
Types of Gate Triggering: DC, AC and Pulse
Gate triggering comes in three forms: DC, AC and pulse. Among practical SCR triggering methods, pulse triggering wins because it keeps gate loss low and the control side isolated.
DC triggering drives the gate continuously from a DC source, which wastes gate power, gives no isolation and adds heating in the reverse half cycle.
AC triggering takes the gate signal from the same AC supply through a resistor or RC network, with a diode to block negative gate voltage.
Pulse triggering sends short current pulses at the chosen firing angle, so average gate power is small, and a pulse transformer or optocoupler gives the isolation needed between a low voltage controller and the 230 V power circuit.

The pulse must stay on long enough for anode current to rise past the latching current IL. With an inductive load, current rises slowly, so designers use a wider pulse or a pulse train.
RC Triggering Circuit of SCR
An RC triggering circuit delays the gate voltage with a capacitor charged through a variable resistor, so the SCR fires later in each half cycle. Of the simple AC SCR triggering methods, it extends the firing range beyond the 0 to 90 degree limit of resistance triggering.
Resistance triggering cannot fire later than 90 degrees because gate voltage peaks with the supply. The capacitor shifts that phase; see our page on RC and RL time constants.
RC ≥ 1.3 × (T / 2)
50 Hz supply: T = 20 ms, so RC ≥ 13 ms
With C = 0.47 µF: R ≥ 13 ms / 0.47 µF = 27.7 k ohm
A larger R slows the charge, giving a later firing angle and a lower average load voltage.
UJT Triggering Circuit for SCR
A UJT triggering circuit uses a unijunction transistor relaxation oscillator to make sharp pulses that fire the SCR through a pulse transformer. It is the classic lab circuit for pulse based SCR triggering methods.
T = R × C × ln[1 / (1 minus η)]
R = 10 k ohm, C = 0.1 µF, η = 0.63
T = 1 ms × 0.994 = 0.994 ms, so f ≈ 1 kHz
C charges through R to the UJT peak point voltage, then dumps through emitter and base 1 into the pulse transformer. A zener clipped supply from the same AC line resets it at each zero crossing, keeping pulses in step with the mains.
Modern boards use a firing IC, a microcontroller timer or a 555 timer instead. The idea is the same: a timed pulse after each zero crossing.
The UJT standoff ratio η typically lies between about 0.5 and 0.8, so the period stays close to RC.
How to Calculate the SCR Gate Resistor
To calculate the SCR gate resistor, subtract VGT from the drive voltage and divide by the gate current you want, which is the datasheet maximum IGT times a margin factor. A margin of about 2 covers cold starts and part to part spread.
Vg = 12 V, VGT = 1.5 V, IGT max = 30 mA, k = 2
Ig = k × IGT = 2 × 30 = 60 mA
Rg = (12 minus 1.5) / 0.060 = 175 ohm
P = 0.060² × 175 = 0.63 W for DC drive

The nearest standard E12 value is 180 ohm, which gives 10.5 / 180 = 58.3 mA, still almost twice IGT. With pulse drive, average resistor power falls by the duty cycle, but you should still check peak gate current against the datasheet IGM rating using Ohm law.
Once the SCR conducts, on state drop times load current heats it, so size the cooling with our heat sink calculator; a hot junction can bring temperature triggering back into play.
These tools cover the cooling, formulas and theory that sit around SCR triggering methods on a real firing board.
Troubleshooting: Why an SCR Will Not Turn On
An SCR that will not turn on usually has too little gate voltage or current, a pulse too short for the load, or load current below the latching value. Work through the flowchart from the top, starting at the gate.

| Symptom | Likely cause | Fix |
|---|---|---|
| No firing at all | Gate polarity reversed or open pulse winding | Check G and K wiring, test pulse on scope |
| Fires warm, fails cold | IGT rises at low temperature | Increase gate current margin |
| Fires, drops out at once | Pulse ends before IL is reached | Wider pulse or pulse train |
| Fires without a pulse | dv/dt or noise on gate | Add RC snubber and RGK resistor |
False firing from line transients is the opposite problem, and the cure is an RC network across the device. Our guide on RC snubber circuit design shows how to size it, and the same physics drives the dv/dt filter used on VFD outputs.
Measure gate voltage directly between gate and cathode at the device terminals with an isolated scope probe. A reading taken at the driver board misses drops in long twisted pair runs and loose connectors.
- Gate pulse amplitude above VGT at the SCR terminals
- Gate current at least twice the cold IGT
- Pulse width long enough for the load to reach IL
- Heat sink sized for full load on state loss
- Fuse rated to protect the SCR I²t
For the fuse, our fuse selection guide explains I²t coordination. Semiconductor fuses must clear before the SCR surge rating is exceeded.
Video: SCR Turn On Methods
This lecture from Simplified EEE Studies explains SCR triggering methods using the VI characteristic.
For the triac and its four triggering quadrants, see our page on thyristors and triacs.
SCR Triggering Methods FAQ
The five SCR triggering methods are forward voltage, dv/dt, temperature, light and gate triggering. Gate triggering is the standard method because it sets the firing angle precisely.
The first three are faults to prevent, while light triggering suits HVDC valves.
Pulse triggering keeps average gate power low, because current flows only for tens of microseconds each cycle. It also allows isolation through a pulse transformer or optocoupler.
DC triggering heats the gate continuously and adds heating in the reverse half cycle.
Take the drive voltage, subtract VGT, then divide by the gate current, which is IGT times a margin of about 2. For 12 V, 1.5 V and 30 mA, Rg = 10.5 / 0.060 = 175 ohm.
Then check resistor power, here 0.63 W for DC drive, and pick the nearest standard value of 180 ohm.
Latching current IL is the minimum anode current needed to keep the SCR on just after the gate pulse is removed. Holding current IH is the lower current below which a conducting SCR turns off.
IL is usually two to three times IH, so the gate pulse must last until load current crosses IL.
False firing usually comes from dv/dt triggering by line transients, gate noise or high junction temperature. A fast voltage rise charges junction capacitance and the current acts like gate current.
Fit an RC snubber, a 1 k ohm gate to cathode resistor and twisted gate leads.
Related Articles
- Silicon Controlled Rectifiers Basics
- Thyristor and Triac Working
- RC Snubber Circuit Design
- Optocoupler Working Principle
- Soft Starter Working Principle
External References
- Littelfuse AN1001: Fundamental Characteristics of Thyristors (PDF)
- Electronics Notes: Thyristor SCR Circuit Design and Triggering
- Wikipedia: Silicon Controlled Rectifier
What We Learn Today
- SCR triggering methods include forward voltage, dv/dt, temperature, light and gate triggering, and only gate and light triggering give a controlled firing instant.
- Pulse gate triggering through a pulse transformer or optocoupler keeps gate loss low, isolates the controller and handles inductive loads with wider pulses or pulse trains.
- Size the gate resistor as drive voltage minus VGT divided by twice IGT, then check resistor power, peak gate current and the cold temperature datasheet values.