Resettable Fuse: 6 Smart Steps for Safe, Reliable Designs

Share:
Electronic Components
Resettable Fuse: 6 Smart Steps for Safe, Reliable Designs

A glass fuse protects a circuit once and then needs a hand to replace it. A polymer PTC device trips on overload, limits the current to a trickle and recovers on its own after the fault and power are removed.

PPTC Polyfuse Hold and Trip Current Time to Trip Temperature Derating R1max

USB ports, battery packs and sensor supplies all need overcurrent protection that survives repeated faults. The PPTC resettable fuse does this job, provided you size its hold current for the hottest ambient and the real load.

Hello everyone, today we are going to learn how a resettable fuse works, what hold current, trip current and time to trip mean, and how to derate and select one correctly.
resettable fuse

What Is a Resettable Fuse?

A resettable fuse is a polymeric positive temperature coefficient device, called PPTC or polyfuse, whose resistance jumps sharply when overcurrent heats it, and which returns to low resistance once the fault is removed and it cools. It is a close relative of the ceramic PTC element described in NTC and PTC thermistor working.

Unlike a conventional fuse link from the fuse selection guide, it never opens fully. It limits current to a small leakage level and holds the circuit in that safe state until power is cycled.

Thermal expansion model and internal structure of a polymer PTC resettable fuse with conductive particles
Image credit: element14. Diagram courtesy of element14, shown here for educational reference.

Inside the device, carbon black particles are spread through a semi crystalline polymer. At normal temperature the particles touch and form conductive chains, so resistance is only a fraction of an ohm.

Advertisement

How a PPTC Polyfuse Trips and Resets

Normal CurrentLow resistance, heat escapes to the board
OvercurrentI²R heating exceeds the heat lost to surroundings
Polymer ExpandsCrystalline regions melt and break carbon chains
Tripped StateResistance rises by many decades, current falls to milliamps
ResetFault and power removed, polymer cools and chains reform

While tripped, the small leakage current keeps the device hot enough to stay in the high resistance state. That is why a tripped resettable fuse usually recovers only after the supply is switched off or the fault is cleared.

The process is purely thermal, so ambient temperature, board copper and nearby parts all affect trip behaviour. This is also why it cannot react as fast as a TVS diode to a voltage spike.

Do You Know?

A tripped PPTC does not return to its original resistance straight away. Eaton defines the post trip resistance R1max as the value measured one hour after a trip, which is higher than the initial resistance.

Key Resettable Fuse Datasheet Parameters

SymbolMeaningWhy It Matters
IholdLargest current held without tripping at 23 °CMust exceed your normal load
ItripSmallest current that surely trips at 23 °CSets fault detection level
VmaxHighest voltage the tripped device withstandsMust exceed supply voltage
ImaxLargest fault current it survivesMust exceed prospective fault
PdPower dissipated in tripped stateHeats nearby parts
Time to tripMaximum time to trip at a stated currentShows protection speed
Ri and R1maxInitial and post trip resistanceAffects voltage drop

Eaton defines hold current as the maximum current the device can carry for 4 hours or longer at 23 °C without tripping. Trip current is the minimum current that will interrupt the circuit at 23 °C, and between the two lies a zone where tripping may or may not happen.

20 mA to 100 AAvailable hold range
Minus 40 to 85 °CCommon operating range
4 hoursHold test duration
About 2 ×Typical trip to hold ratio

element14 notes that resettable devices cover protection levels from about 20 mA up to 100 A, and that most work over minus 40 °C to 85 °C. Many datasheets list trip current at roughly twice the hold current, though you must read the exact figure for each part.

Temperature Derating of a Resettable Fuse

Because trip action is thermal, a hot ambient brings the device closer to tripping, and both hold and trip currents fall. Eaton shows an example family where the rating rises to about 130 percent at minus 20 °C and falls to about 50 percent at 80 °C.

Minimum rated hold: Ihold ≥ Iload ÷ Kt
Trip at 23 °C: Itrip ≈ Ihold × trip ratio
Trip at ambient: Itrip,amb = Itrip × Kt

Kt = derating factor at the highest ambient, from the datasheet

Example:
Iload = 0.5 A, Kt = 75 % at 60 °C, trip ratio = 2
Ihold ≥ 0.5 ÷ 0.75 = 0.67 A
Itrip ≈ 0.67 × 2 = 1.33 A at 23 °C
Itrip at 60 °C ≈ 1.33 × 0.75 = 1.00 A

Pick the next standard hold rating above 0.67 A, for example 0.75 A, then confirm that the derated trip current still falls below the current your wiring and regulator can safely supply. Always use the derating table of the exact series you buy.

Resettable Fuse Sizing Calculator

Hold and Trip Current With Derating
Result
Minimum hold rating 0.67 A, trip about 1.33 A at 23 °C and 1.00 A at your ambient
Advertisement

Second Worked Example: A 5 V USB Port

A USB 2.0 port must supply 0.5 A, and many boards, including the popular Arduino Uno, protect it with a 500 mA polyfuse. The same idea protects a microcontroller board from a shorted cable or a faulty peripheral.

If the device has an initial resistance of 0.3 Ω, the drop at 0.5 A is 0.5 × 0.3 = 0.15 V, by Ohm law. After a trip, resistance may settle nearer R1max, so check that 5 V minus the new drop still meets the USB minimum.

Quick Tip

Place the resettable fuse away from regulators and power resistors on the PCB. Heat from a neighbour derates it silently and causes nuisance trips on hot days.

6 Smart Steps to Select a Resettable Fuse

1
Define the Circuit
Note normal current, supply voltage, fault current and ambient range.
2
Apply Derating
Divide load current by the derating factor to get the minimum hold rating.
3
Check Maximums
Confirm Vmax and Imax exceed the supply voltage and prospective fault.
4
Check Time to Trip
Compare the trip curve with the time the load can survive the fault.
5
Verify Temperature Range
Ensure the part is rated for the full operating and storage range.
6
Confirm Package
Check footprint, mounting, reflow profile and approvals.

Eaton recommends a six step process of this kind in its application note. The fault current in step three comes from the source impedance, just as in short circuit current calculation for larger systems.

Resettable Fuse Packages and Types

Surface Mount

Chip packages from 0402 to 2920 for boards and ports.

Best for: USB, HDMI and sensor supplies
Compact
Radial Leaded

Disc on two leads, higher hold currents and voltages.

Best for: power supplies and panels
Robust
Axial Battery Strap

Flat strip welded between cells in a pack.

Best for: lithium battery packs
Thin
High Voltage Telecom

Rated for line voltages and power cross faults.

Best for: telephone and data lines
Surge rated

element14 describes the Bel 0ZSC axial battery strap series as handling 1.2 to 4.2 A at 15 to 30 V DC. Such straps protect packs from shorts that are a common cause in causes of battery failure.

Resettable Fuse vs Glass Fuse

FeaturePPTC DeviceGlass or Ceramic Fuse
After a faultResets itselfMust be replaced
Tripped stateSmall leakage currentFully open circuit
SpeedSlower, thermalFast or slow blow options
Voltage ratingUsually low voltage DCUp to mains and higher
ResistanceHigher, changes after tripVery low and stable

For mains circuits, high fault levels and safety isolation, a proper fuse or a breaker from MCB, MCCB, ELCB and RCCB remains the right choice. The PPTC suits low voltage electronics where faults are frequent and replacement is inconvenient.

Myth: A resettable fuse fully disconnects the load.
Fact: It only limits current to a small leakage level, so the circuit is not isolated.
Myth: It resets instantly after tripping.
Fact: It stays tripped while power and fault remain, and resistance recovers over time.
Myth: Hold current is the same in any enclosure.
Fact: Hold current falls as ambient temperature rises, so derating is essential.
Myth: It can replace every fuse.
Fact: Vmax and Imax limits make it unsuitable for mains and high fault circuits.
Advertisement

Troubleshooting Nuisance Trips and Failures

  • Measure real load current, including inrush and motor start.
  • Check local temperature near the device with a thermal camera.
  • Confirm the derated hold current still exceeds the load.
  • Measure device resistance after cooling for one hour.
  • Check that the supply stays below the Vmax rating.
  • Look for heat from nearby regulators or resistors.
  • Confirm pad and copper area match the datasheet test board.

Motor loads such as a small brushless DC motor draw a starting surge that can trip an undersized part. Capacitive loads behave similarly, so bulk and decoupling capacitors must be included in the inrush check.

Copper area changes heat loss, so a device on a thin trace trips earlier than one on a wide pour. Guidance on copper sizing is given in PCB trace width calculator.

Quick Tip

Never test a PPTC by repeated shorts at full fault current on the bench. Each trip ages the polymer a little and raises its resistance, so limit test trips to what the datasheet allows.

Do You Know?

The polymer switching effect resembles the thermal action of a bimetal overload relay. Both depend on heat, which is why ambient temperature changes the trip point in each case.

Advantages of a Resettable Fuse
  • Resets itself, no replacement or spares.
  • Small surface mount packages.
  • Handles repeated overloads well.
  • Low cost for low voltage protection.
Limitations
  • Slower than a fast blow fuse.
  • Leakage current flows while tripped.
  • Resistance rises after each trip.
  • Limited voltage and fault current ratings.

Where Polyfuses Are Used

USB and HDMI Ports
Protect hosts from shorted cables and devices.
Battery Packs
Straps between cells stop short circuit damage.
Sensor Supplies
Loop and field supplies in automation panels.
Motors and Fans
Stall protection in small DC motor circuits.
Telecom Lines
Protection from power cross and line faults.

In automation panels, a resettable fuse protects each transmitter branch of a 4 to 20 mA current loop supply, so one shorted cable does not collapse the whole card. A thermal overload relay does a similar job at motor power levels.

Eaton PTC Resettable Fuse Application Guide

PDF
Eaton Bussmann Series PTC Resettable Fuse Application Guidelines
Eaton technical note covering definitions, derating and a six step selection method

Polyfuse Bench Test Video

Resettable Fuse FAQ

What is a resettable fuse?

It is a polymeric PTC device whose resistance rises sharply when overcurrent heats it. It limits the current to a small leakage level instead of opening like a normal fuse.

When the fault and power are removed, the polymer cools and resistance falls again. The circuit can then work normally without any part being replaced.

What is the difference between hold and trip current?

Hold current is the largest current the device carries for hours at 23 °C without tripping. Trip current is the smallest current that is sure to trip it at that same reference temperature.

Between the two values the device may or may not trip. Many datasheets list trip current at roughly twice the hold current for a given part.

Why must I derate a PPTC for temperature?

The trip action is thermal, so a hot ambient leaves less margin before tripping. Hold and trip currents both fall as the surroundings get warmer.

Eaton shows an example where the rating is about 130 percent at minus 20 °C and only 50 percent at 80 °C ambient temperature. Always divide the load current by the derating factor.

Does a resettable fuse reset immediately?

No, it stays tripped while the supply and the fault remain because leakage current keeps it hot. It resets only after the fault is cleared or the power is cycled.

Its resistance also recovers slowly and may remain above the initial value. Eaton measures the post trip value R1max one hour after a trip for this reason.

Can a polyfuse replace a mains fuse?

Usually not, because most parts are rated for low DC voltages and limited fault currents. Exceeding Vmax or Imax can destroy the device instead of protecting the circuit.

Mains circuits need a proper fuse or circuit breaker with the correct breaking capacity. Special high voltage PPTC parts do exist, but they are made mainly for telecom line protection.

How do I choose a resettable fuse for a USB port?

Start with the port current, for example 0.5 A for a USB 2.0 port, and the highest board temperature. Divide the current by the derating factor to get the minimum hold rating.

Then check Vmax, Imax, time to trip and the voltage drop across the device. The Arduino Uno uses a 500 mA polyfuse on its USB supply as an example.

Why does my polyfuse trip at normal load?

The most common cause is heat from nearby parts or a hot enclosure. Another is inrush current from motors or large capacitors at switch on.

Measure the real current and local temperature, then compare them with the derated hold rating. A small copper area around the pads can also cause early tripping, because the device loses heat more slowly.

Advertisement

Related Articles

External References

What We Learn Today

  • A resettable fuse is a polymer PTC device that trips by self heating, limits current to a small leakage and recovers once the fault clears.
  • Hold current is held for 4 hours at 23 °C without tripping, while trip current is the minimum that surely trips, often about twice the hold value.
  • Divide load current by the datasheet derating factor, so 0.5 A at 75 percent needs at least 0.67 A hold, then check Vmax and Imax.
I hope you like above blog. There is no cost associated in sharing the article in your social media. Thanks for reading!! Happy Learning!!

Leave a Reply

Your email address will not be published. Required fields are marked *

Support free learning

Help keep every guide, calculator and tool 100% free

Hosting, software and hours of research go into every article. Even a small contribution helps us publish more in-depth guides for students, technicians and engineers.

  • No paywalls
  • No sign up
  • Free for everyone