Table of Contents
ToggleA glass fuse protects a circuit once and then needs a hand to replace it. A polymer PTC device trips on overload, limits the current to a trickle and recovers on its own after the fault and power are removed.
USB ports, battery packs and sensor supplies all need overcurrent protection that survives repeated faults. The PPTC resettable fuse does this job, provided you size its hold current for the hottest ambient and the real load.

What Is a Resettable Fuse?
A resettable fuse is a polymeric positive temperature coefficient device, called PPTC or polyfuse, whose resistance jumps sharply when overcurrent heats it, and which returns to low resistance once the fault is removed and it cools. It is a close relative of the ceramic PTC element described in NTC and PTC thermistor working.
Unlike a conventional fuse link from the fuse selection guide, it never opens fully. It limits current to a small leakage level and holds the circuit in that safe state until power is cycled.

Inside the device, carbon black particles are spread through a semi crystalline polymer. At normal temperature the particles touch and form conductive chains, so resistance is only a fraction of an ohm.
How a PPTC Polyfuse Trips and Resets
While tripped, the small leakage current keeps the device hot enough to stay in the high resistance state. That is why a tripped resettable fuse usually recovers only after the supply is switched off or the fault is cleared.
The process is purely thermal, so ambient temperature, board copper and nearby parts all affect trip behaviour. This is also why it cannot react as fast as a TVS diode to a voltage spike.
A tripped PPTC does not return to its original resistance straight away. Eaton defines the post trip resistance R1max as the value measured one hour after a trip, which is higher than the initial resistance.
Key Resettable Fuse Datasheet Parameters
| Symbol | Meaning | Why It Matters |
|---|---|---|
| Ihold | Largest current held without tripping at 23 °C | Must exceed your normal load |
| Itrip | Smallest current that surely trips at 23 °C | Sets fault detection level |
| Vmax | Highest voltage the tripped device withstands | Must exceed supply voltage |
| Imax | Largest fault current it survives | Must exceed prospective fault |
| Pd | Power dissipated in tripped state | Heats nearby parts |
| Time to trip | Maximum time to trip at a stated current | Shows protection speed |
| Ri and R1max | Initial and post trip resistance | Affects voltage drop |
Eaton defines hold current as the maximum current the device can carry for 4 hours or longer at 23 °C without tripping. Trip current is the minimum current that will interrupt the circuit at 23 °C, and between the two lies a zone where tripping may or may not happen.
element14 notes that resettable devices cover protection levels from about 20 mA up to 100 A, and that most work over minus 40 °C to 85 °C. Many datasheets list trip current at roughly twice the hold current, though you must read the exact figure for each part.
Temperature Derating of a Resettable Fuse
Because trip action is thermal, a hot ambient brings the device closer to tripping, and both hold and trip currents fall. Eaton shows an example family where the rating rises to about 130 percent at minus 20 °C and falls to about 50 percent at 80 °C.
Trip at 23 °C: Itrip ≈ Ihold × trip ratio
Trip at ambient: Itrip,amb = Itrip × Kt
Kt = derating factor at the highest ambient, from the datasheet
Example:
Iload = 0.5 A, Kt = 75 % at 60 °C, trip ratio = 2
Ihold ≥ 0.5 ÷ 0.75 = 0.67 A
Itrip ≈ 0.67 × 2 = 1.33 A at 23 °C
Itrip at 60 °C ≈ 1.33 × 0.75 = 1.00 A
Pick the next standard hold rating above 0.67 A, for example 0.75 A, then confirm that the derated trip current still falls below the current your wiring and regulator can safely supply. Always use the derating table of the exact series you buy.
Resettable Fuse Sizing Calculator
Second Worked Example: A 5 V USB Port
A USB 2.0 port must supply 0.5 A, and many boards, including the popular Arduino Uno, protect it with a 500 mA polyfuse. The same idea protects a microcontroller board from a shorted cable or a faulty peripheral.
If the device has an initial resistance of 0.3 Ω, the drop at 0.5 A is 0.5 × 0.3 = 0.15 V, by Ohm law. After a trip, resistance may settle nearer R1max, so check that 5 V minus the new drop still meets the USB minimum.
Place the resettable fuse away from regulators and power resistors on the PCB. Heat from a neighbour derates it silently and causes nuisance trips on hot days.
6 Smart Steps to Select a Resettable Fuse
Eaton recommends a six step process of this kind in its application note. The fault current in step three comes from the source impedance, just as in short circuit current calculation for larger systems.
Resettable Fuse Packages and Types
Chip packages from 0402 to 2920 for boards and ports.
Disc on two leads, higher hold currents and voltages.
Flat strip welded between cells in a pack.
Rated for line voltages and power cross faults.
element14 describes the Bel 0ZSC axial battery strap series as handling 1.2 to 4.2 A at 15 to 30 V DC. Such straps protect packs from shorts that are a common cause in causes of battery failure.
Resettable Fuse vs Glass Fuse
| Feature | PPTC Device | Glass or Ceramic Fuse |
|---|---|---|
| After a fault | Resets itself | Must be replaced |
| Tripped state | Small leakage current | Fully open circuit |
| Speed | Slower, thermal | Fast or slow blow options |
| Voltage rating | Usually low voltage DC | Up to mains and higher |
| Resistance | Higher, changes after trip | Very low and stable |
For mains circuits, high fault levels and safety isolation, a proper fuse or a breaker from MCB, MCCB, ELCB and RCCB remains the right choice. The PPTC suits low voltage electronics where faults are frequent and replacement is inconvenient.
Troubleshooting Nuisance Trips and Failures
- Measure real load current, including inrush and motor start.
- Check local temperature near the device with a thermal camera.
- Confirm the derated hold current still exceeds the load.
- Measure device resistance after cooling for one hour.
- Check that the supply stays below the Vmax rating.
- Look for heat from nearby regulators or resistors.
- Confirm pad and copper area match the datasheet test board.
Motor loads such as a small brushless DC motor draw a starting surge that can trip an undersized part. Capacitive loads behave similarly, so bulk and decoupling capacitors must be included in the inrush check.
Copper area changes heat loss, so a device on a thin trace trips earlier than one on a wide pour. Guidance on copper sizing is given in PCB trace width calculator.
Never test a PPTC by repeated shorts at full fault current on the bench. Each trip ages the polymer a little and raises its resistance, so limit test trips to what the datasheet allows.
The polymer switching effect resembles the thermal action of a bimetal overload relay. Both depend on heat, which is why ambient temperature changes the trip point in each case.
- Resets itself, no replacement or spares.
- Small surface mount packages.
- Handles repeated overloads well.
- Low cost for low voltage protection.
- Slower than a fast blow fuse.
- Leakage current flows while tripped.
- Resistance rises after each trip.
- Limited voltage and fault current ratings.
Where Polyfuses Are Used
In automation panels, a resettable fuse protects each transmitter branch of a 4 to 20 mA current loop supply, so one shorted cable does not collapse the whole card. A thermal overload relay does a similar job at motor power levels.
Eaton PTC Resettable Fuse Application Guide
Polyfuse Bench Test Video
Resettable Fuse FAQ
It is a polymeric PTC device whose resistance rises sharply when overcurrent heats it. It limits the current to a small leakage level instead of opening like a normal fuse.
When the fault and power are removed, the polymer cools and resistance falls again. The circuit can then work normally without any part being replaced.
Hold current is the largest current the device carries for hours at 23 °C without tripping. Trip current is the smallest current that is sure to trip it at that same reference temperature.
Between the two values the device may or may not trip. Many datasheets list trip current at roughly twice the hold current for a given part.
The trip action is thermal, so a hot ambient leaves less margin before tripping. Hold and trip currents both fall as the surroundings get warmer.
Eaton shows an example where the rating is about 130 percent at minus 20 °C and only 50 percent at 80 °C ambient temperature. Always divide the load current by the derating factor.
No, it stays tripped while the supply and the fault remain because leakage current keeps it hot. It resets only after the fault is cleared or the power is cycled.
Its resistance also recovers slowly and may remain above the initial value. Eaton measures the post trip value R1max one hour after a trip for this reason.
Usually not, because most parts are rated for low DC voltages and limited fault currents. Exceeding Vmax or Imax can destroy the device instead of protecting the circuit.
Mains circuits need a proper fuse or circuit breaker with the correct breaking capacity. Special high voltage PPTC parts do exist, but they are made mainly for telecom line protection.
Start with the port current, for example 0.5 A for a USB 2.0 port, and the highest board temperature. Divide the current by the derating factor to get the minimum hold rating.
Then check Vmax, Imax, time to trip and the voltage drop across the device. The Arduino Uno uses a 500 mA polyfuse on its USB supply as an example.
The most common cause is heat from nearby parts or a hot enclosure. Another is inrush current from motors or large capacitors at switch on.
Measure the real current and local temperature, then compare them with the derated hold rating. A small copper area around the pads can also cause early tripping, because the device loses heat more slowly.
Related Articles
- NTC and PTC Thermistor Working
- Fuse Selection Guide
- TVS Diode Transient Voltage Suppression
- MCB vs MCCB vs ELCB vs RCCB
- Causes of Battery Failure
External References
- Eaton Bussmann Series PTC Resettable Fuse Application Guidelines, Eaton
- A Comprehensive Guide to Resettable Fuses, element14
- Resettable Fuse, Wikipedia
What We Learn Today
- A resettable fuse is a polymer PTC device that trips by self heating, limits current to a small leakage and recovers once the fault clears.
- Hold current is held for 4 hours at 23 °C without tripping, while trip current is the minimum that surely trips, often about twice the hold value.
- Divide load current by the datasheet derating factor, so 0.5 A at 75 percent needs at least 0.67 A hold, then check Vmax and Imax.