Articles

Pressure to Head Conversion Calculator & Formula Table

Pressure Measurement Pressure to Head Conversion: How to Convert Bar, PSI and kPa into Metres or Feet of Liquid Head Pressure and head describe the.

Learn More

Pipe Flow Velocity Calculator, Formula & Solved Example

Flow Measurement Pipe Flow Velocity: How to Calculate Velocity from Flow Rate and Pipe Diameter, with Recommended Ranges for Liquids, Gas and Steam Velocity is.

Learn More

Instrument Air Header Sizing: Solved Example & Calculator

Design Instrument Air Header Sizing: Load Summation, Velocity and Pressure Drop Rules, Ring Main Layout, Receiver Sizing and a Pipe ID Calculator An instrument air.

Learn More

HART Communicator Calibration: Steps, Table & Calculator

Calibration HART Communicator Calibration: Sensor Trim, Output Trim, Rerange and Loop Test of a Pressure Transmitter With a Solved Example and mA Error Calculator A.

Learn More

Control Valve Maintenance: Checklist & Air Leak Calculator

Control Valves Control Valve Maintenance: Preventive vs Predictive Strategy, Inspection Checklist, Packing, Trim, Seat Leak Test, Bench Set and Diagnostics A control valve wears quietly.

Learn More

Flow Switch Setpoint: How to Set It & Calculator

Switches Flow Switch Setpoint: How to Choose, Adjust and Test the Trip Point on Paddle, Thermal Dispersion and DP Flow Switches A flow switch only.

Learn More

Turbidity Sensor Calibration: Steps & Dilution Calculator

Analytical Turbidity Sensor Calibration: NTU and FNU Units, ISO 7027 vs EPA 180.1, Formazin and StablCal Standards, Dilution and Troubleshooting A turbidity reading is only.

Learn More

RTD vs Thermistor: Comparison Table & Slope Calculator

Temperature RTD vs Thermistor: Range, Accuracy, Sensitivity, Self Heating, Wiring and Cost Compared With a Solved Example and Slope Calculator Both sensors change resistance with.

Learn More

Radar Level Transmitter Calibration: Steps & Calculator

Level Radar Level Transmitter Calibration: Reference Height, Empty and Full Distance, Blocking Distance, Level Offset, False Echo Mapping and 4 to 20 mA Checks A.

Learn More

Filter Differential Pressure: Change Out Chart & Calculator

Pressure Filter Differential Pressure: Clean vs Dirty Values, Change Out Setpoints, DP Gauges, Switches and Transmitters, Flow Correction and Troubleshooting A pressure gauge on each.

Learn More
Support free learning

Help keep every guide, calculator and tool 100% free

Hosting, software and hours of research go into every article. Even a small contribution helps us publish more in-depth guides for students, technicians and engineers.

  • No paywalls
  • No sign up
  • Free for everyone