DeviceNet Protocol: 4 Facts Behind Every Node

Share:
Instrumentation
DeviceNet Protocol: 4 Facts Behind Every Node

A network built on the same CAN bus technology found in a modern automobile still quietly runs sensors, motor starters, and photoeyes across factory floors today.

That network is DeviceNet, and its simple two pair cable hides a surprisingly rigid set of rules that keep every node talking cleanly.

DeviceNet Protocol CAN Bus CIP ODVA

DeviceNet Protocol combines a CAN based physical layer with the Common Industrial Protocol, letting sensors, actuators, and motor starters share both power and data on a single trunk and drop line network.

Hello everyone, today we are going to walk through what actually makes DeviceNet tick, from its cabling and node limits through to its place inside the wider CIP family of networks.

We will cover baud rate versus distance tradeoffs, power budget limits, wiring cautions, and how it compares against a fieldbus like Profibus DP.
DeviceNet Protocol
Advertisement

4 Facts That Define DeviceNet

1
CAN Based Physical Layer
Built on the same Controller Area Network technology originally developed for the automotive industry.
2
Trunk and Drop Topology
A main trunk line feeds shorter drop lines out to each individual device on the network.
3
CIP Application Layer
Uses the Common Industrial Protocol object model, the same layer shared with EtherNet IP and ControlNet.
4
Power on the Cable
Carries 24 volts DC alongside the data signal, so many small devices need no separate power wiring.

Baud Rate Sets the Maximum Trunk Length

Baud RateMaximum Trunk Length
125 kbpsAbout 500 meters
250 kbpsAbout 250 meters
500 kbpsAbout 100 meters

Faster is not always better here, which is why most real installations run at the lowly 125 kbps setting rather than chasing the fastest option available.

A drop line can extend up to 6 meters from the trunk, with the cumulative length of every drop combined capped depending on the chosen baud rate.

Advertisement

Node Count and Power Budget Limits

Maximum Nodes
64 devices, addressed 0 through 63
Trunk Line Current
Up to about 8 amps
Drop Line Current
Up to about 3 amps
Termination Resistor
About 121 ohms at each trunk end

Duplicate node addresses are not allowed, and a device that boots up with an address already in use will trigger a communication fault rather than joining quietly.

Did You Know
DeviceNet shares its application layer, the Common Industrial Protocol, with two other networks, EtherNet IP and ControlNet. A device built around the CIP object model can be understood the same way regardless of which of these three physical networks it actually rides on.

DeviceNet Compared to Profibus DP

DeviceNet

CAN based, low cost, device level network suited to simple sensors and actuators, sharing power and data on one cable.

Profibus DP

RS485 based, generally used for higher level device integration such as drives, with longer reach at its lower baud rates.

Advertisement

Wiring Cautions Worth Remembering

1
Never reverse the CAN High and CAN Low lines, since that alone can cause a complete network failure.
2
Use diode isolation whenever more than one power supply feeds the same trunk line.
3
Watch the total connected load against the trunk and drop current limits before adding more devices.
4
Confirm both trunk ends carry a termination resistor, not just the end nearest the scanner module.
Tip
Every DeviceNet device ships with an Electronic Data Sheet file describing its CIP object model to configuration software. Keep these files organized by device and firmware revision, since a mismatched or missing EDS file is a common reason a device configures incorrectly during commissioning.

Where DeviceNet Protocol Shows Up on the Floor

Photoeyes, motor starters, pneumatic valve manifolds, push buttons, and simple flow switches make up most of what actually rides a DeviceNet Protocol network in a real plant.

These are exactly the kind of low cost, device level nodes that never needed the bandwidth of a newer Ethernet based network in the first place.

That is also why so many of these installations remain in service today, since replacing a working DeviceNet Protocol segment rarely earns back the cost of the upgrade.

Watch: What Is DeviceNet

DeviceNet Protocol Questions Engineers Ask

How many devices can one DeviceNet network support?
Up to 64 nodes, addressed zero through sixty three, with every address required to stay unique on the network.
Why does DeviceNet carry power on the same cable as data?
It simplifies wiring for small sensors and actuators, letting many devices skip a separate power run entirely.
What happens if I run DeviceNet at the fastest baud rate?
The maximum trunk length shrinks considerably, which is why most installations stick with the slower 125 kbps setting instead.
Is DeviceNet related to EtherNet IP?
Yes, both share the same Common Industrial Protocol application layer, just riding on different physical networks underneath.
Who maintains the DeviceNet specification today?
ODVA, the Open DeviceNet Vendors Association, maintains DeviceNet after it was originally developed by Rockwell Automation.

Related Articles on This Site

External References

Advertisement

What We Learn Today

  • DeviceNet Protocol pairs a CAN based physical layer with the CIP application layer used across the wider ODVA network family.
  • Baud rate and maximum trunk length trade against each other, which is why 125 kbps remains the common choice.
  • Node addressing, power budget limits, and correct wiring polarity all matter for a stable installation.
I hope you like above blog. There is no cost associated in sharing the article in your social media. Thanks for reading!! Happy Learning!!